new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 18

Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8

We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4~eV at 6~keV at a rate of about 1~c/s/pixel. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of about 2 x 10^3 c/s/all pixels with an energy resolution of 5 eV at 6 keV. By utilizing the TES's wide-band spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted X-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As K alpha and Pb L alpha2 of the standard sample were clearly resolved and the XANES of Pb L alpha2 was obtained. Moreover, the X-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard X-ray synchrotron facilities.

  • 43 authors
·
Apr 22

Indirect dark matter searches at ultrahigh energy neutrino detectors

High to ultrahigh energy neutrino detectors can uniquely probe the properties of dark matter χ by searching for the secondary products produced through annihilation and/or decay processes. We evaluate the sensitivities to dark matter thermally averaged annihilation cross section langleσvrangle and partial decay width into neutrinos Γ_{χrightarrowνbarν} (in the mass scale 10^7 leq m_χ/{rm GeV} leq 10^{15}) for next generation observatories like POEMMA and GRAND. We show that in the range 10^7 leq m_χ/{rm GeV} leq 10^{11}, space-based Cherenkov detectors like POEMMA have the advantage of full-sky coverage and rapid slewing, enabling an optimized dark matter observation strategy focusing on the Galactic center. We also show that ground-based radio detectors such as GRAND can achieve high sensitivities and high duty cycles in radio quiet areas. We compare the sensitivities of next generation neutrino experiments with existing constraints from IceCube and updated 90\% C.L. upper limits on langleσvrangle and Γ_{χrightarrowνbarν} using results from the Pierre Auger Collaboration and ANITA. We show that in the range 10^7 leq m_χ/{rm GeV} leq 10^{11} POEMMA and GRAND10k will improve the neutrino sensitivity to particle dark matter by factors of 2 to 10 over existing limits, whereas GRAND200k will improve this sensitivity by two orders of magnitude. In the range 10^{11} leq m_χ/{rm GeV} leq 10^{15}, POEMMA's fluorescence observation mode will achieve an unprecedented sensitivity to dark matter properties. Finally, we highlight the importance of the uncertainties related to the dark matter distribution in the Galactic halo, using the latest fit and estimates of the Galactic parameters.

  • 8 authors
·
Jun 8, 2021

Enhancing Fluorescence Lifetime Parameter Estimation Accuracy with Differential Transformer Based Deep Learning Model Incorporating Pixelwise Instrument Response Function

Fluorescence Lifetime Imaging (FLI) is a critical molecular imaging modality that provides unique information about the tissue microenvironment, which is invaluable for biomedical applications. FLI operates by acquiring and analyzing photon time-of-arrival histograms to extract quantitative parameters associated with temporal fluorescence decay. These histograms are influenced by the intrinsic properties of the fluorophore, instrument parameters, time-of-flight distributions associated with pixel-wise variations in the topographic and optical characteristics of the sample. Recent advancements in Deep Learning (DL) have enabled improved fluorescence lifetime parameter estimation. However, existing models are primarily designed for planar surface samples, limiting their applicability in translational scenarios involving complex surface profiles, such as in-vivo whole-animal or imaged guided surgical applications. To address this limitation, we present MFliNet (Macroscopic FLI Network), a novel DL architecture that integrates the Instrument Response Function (IRF) as an additional input alongside experimental photon time-of-arrival histograms. Leveraging the capabilities of a Differential Transformer encoder-decoder architecture, MFliNet effectively focuses on critical input features, such as variations in photon time-of-arrival distributions. We evaluate MFliNet using rigorously designed tissue-mimicking phantoms and preclinical in-vivo cancer xenograft models. Our results demonstrate the model's robustness and suitability for complex macroscopic FLI applications, offering new opportunities for advanced biomedical imaging in diverse and challenging settings.

  • 7 authors
·
Nov 25, 2024

EvidenceMoE: A Physics-Guided Mixture-of-Experts with Evidential Critics for Advancing Fluorescence Light Detection and Ranging in Scattering Media

Fluorescence LiDAR (FLiDAR), a Light Detection and Ranging (LiDAR) technology employed for distance and depth estimation across medical, automotive, and other fields, encounters significant computational challenges in scattering media. The complex nature of the acquired FLiDAR signal, particularly in such environments, makes isolating photon time-of-flight (related to target depth) and intrinsic fluorescence lifetime exceptionally difficult, thus limiting the effectiveness of current analytical and computational methodologies. To overcome this limitation, we present a Physics-Guided Mixture-of-Experts (MoE) framework tailored for specialized modeling of diverse temporal components. In contrast to the conventional MoE approaches our expert models are informed by underlying physics, such as the radiative transport equation governing photon propagation in scattering media. Central to our approach is EvidenceMoE, which integrates Evidence-Based Dirichlet Critics (EDCs). These critic models assess the reliability of each expert's output by providing per-expert quality scores and corrective feedback. A Decider Network then leverages this information to fuse expert predictions into a robust final estimate adaptively. We validate our method using realistically simulated Fluorescence LiDAR (FLiDAR) data for non-invasive cancer cell depth detection generated from photon transport models in tissue. Our framework demonstrates strong performance, achieving a normalized root mean squared error (NRMSE) of 0.030 for depth estimation and 0.074 for fluorescence lifetime.

  • 9 authors
·
May 23, 2025

ProteinJEPA: Latent prediction complements protein language models

Protein language models are trained primarily with masked language modeling (MLM), which predicts amino-acid identities at masked positions. We ask whether latent-space prediction can complement these token-level objectives under matched wall-clock budget. Across pretrained and random-init protein sequence encoders at 35--150M parameters, we find that the best protein-JEPA design is not all-position latent prediction but a variant: predicting latent targets only at masked positions, and retaining the MLM cross-entropy. We call this recipe masked-position MLM+JEPA. On a 16-task downstream suite (15 frozen linear probes plus SCOPe-40 zero-shot fold retrieval), under matched wall-clock budgets, this recipe wins more tasks than it loses against MLM-only continuation: 10 wins / 3 losses / 3 ties (hereafter W/L/T) on pretrained ESM2-35M, 11/2/3 on ESM2-150M while results in pretraining from scratch are mixed (6/8/2). Gains are seen for multiple models on 11 of 16 tasks, including stability, etaβeta-lactamase fitness, variant effect, intrinsic disorder, remote homology, enzyme classification, and SCOPe-40 fold retrieval. Tasks with more losses than wins are Fluorescence (TAPE) and Peptide-HLA Binding. All-position MLM+JEPA matches MLM-only overall but does not reproduce the masked-position gains. JEPA-only (no MLM) collapses in nearly every experiment. We conclude that JEPA, when combined with MLM, is competitive and can outperform pure MLM in pretraining and continued training, even under matched wall-clock budgets.

  • 3 authors
·
May 7 1

A Foundation Model for Spatial Proteomics

Foundation models have begun to transform image analysis by acting as pretrained generalist backbones that can be adapted to many tasks even when post-training data are limited, yet their impact on spatial proteomics, imaging that maps proteins at single-cell resolution, remains limited. Here, we introduce KRONOS, a foundation model built for spatial proteomics. KRONOS was trained in a self-supervised manner on over 47 million image patches covering 175 protein markers, 16 tissue types, and 8 fluorescence-based imaging platforms. We introduce key architectural adaptations to address the high-dimensional, multi-channel, and heterogeneous nature of multiplex imaging. We demonstrate that KRONOS learns biologically meaningful representations across multiple scales, ranging from cellular and microenvironment to tissue levels, enabling it to address diverse downstream tasks, including cell phenotyping, region classification, and patient stratification. Evaluated across 11 independent cohorts, KRONOS achieves state-of-the-art performance across cell phenotyping, treatment response prediction, and retrieval tasks, and is highly data-efficient. KRONOS also introduces the paradigm of segmentation-free patch-level processing for efficient and scalable spatial proteomics analysis, allowing cross-institutional comparisons, and as an image reverse search engine for spatial patterns. Together, these results position KRONOS as a flexible and scalable tool for spatial proteomics. The model is publicly accessible at https://github.com/mahmoodlab/KRONOS.

  • 60 authors
·
Jun 2, 2025

Open Catalyst Experiments 2024 (OCx24): Bridging Experiments and Computational Models

The search for low-cost, durable, and effective catalysts is essential for green hydrogen production and carbon dioxide upcycling to help in the mitigation of climate change. Discovery of new catalysts is currently limited by the gap between what AI-accelerated computational models predict and what experimental studies produce. To make progress, large and diverse experimental datasets are needed that are reproducible and tested at industrially-relevant conditions. We address these needs by utilizing a comprehensive high-throughput characterization and experimental pipeline to create the Open Catalyst Experiments 2024 (OCX24) dataset. The dataset contains 572 samples synthesized using both wet and dry methods with X-ray fluorescence and X-ray diffraction characterization. We prepared 441 gas diffusion electrodes, including replicates, and evaluated them using zero-gap electrolysis for carbon dioxide reduction (CO_2RR) and hydrogen evolution reactions (HER) at current densities up to 300 mA/cm^2. To find correlations with experimental outcomes and to perform computational screens, DFT-verified adsorption energies for six adsorbates were calculated on sim20,000 inorganic materials requiring 685 million AI-accelerated relaxations. Remarkably from this large set of materials, a data driven Sabatier volcano independently identified Pt as being a top candidate for HER without having any experimental measurements on Pt or Pt-alloy samples. We anticipate the availability of experimental data generated specifically for AI training, such as OCX24, will significantly improve the utility of computational models in selecting materials for experimental screening.

  • 20 authors
·
Nov 17, 2024

A Wearable Device Dataset for Mental Health Assessment Using Laser Doppler Flowmetry and Fluorescence Spectroscopy Sensors

In this study, we introduce a novel method to predict mental health by building machine learning models for a non-invasive wearable device equipped with Laser Doppler Flowmetry (LDF) and Fluorescence Spectroscopy (FS) sensors. Besides, we present the corresponding dataset to predict mental health, e.g. depression, anxiety, and stress levels via the DAS-21 questionnaire. To our best knowledge, this is the world's largest and the most generalized dataset ever collected for both LDF and FS studies. The device captures cutaneous blood microcirculation parameters, and wavelet analysis of the LDF signal extracts key rhythmic oscillations. The dataset, collected from 132 volunteers aged 18-94 from 19 countries, explores relationships between physiological features, demographics, lifestyle habits, and health conditions. We employed a variety of machine learning methods to classify stress detection, in which LightGBM is identified as the most effective model for stress detection, achieving a ROC AUC of 0.7168 and a PR AUC of 0.8852. In addition, we also incorporated Explainable Artificial Intelligence (XAI) techniques into our analysis to investigate deeper insights into the model's predictions. Our results suggest that females, younger individuals and those with a higher Body Mass Index (BMI) or heart rate have a greater likelihood of experiencing mental health conditions like stress and anxiety. All related code and data are published online: https://github.com/leduckhai/Wearable_LDF-FS.

  • 10 authors
·
Feb 2, 2025

Mutual Colormap Dependence: How Recoloring Biomedical Images Changes Vision-Language Model Answers

Vision-language models (VLMs) are being built to answer questions about biomedical images, yet they never see the measured intensities, only the colors that a colormap has assigned to them. For questions about image content, the colormap should not change the answer. We call the extent to which it does Mutual Colormap Dependence (MCD), the mutual information between the colormap and a model's answer, which is zero exactly when every colormap yields the same answer distribution. Because VLMs sample their answers, we compare recoloring with a control that uses the same number of calls to ask again about the unchanged gray image, so that ordinary resampling is not mistaken for an effect of the colormap. We test GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6, and Qwen3-VL-235B under six luminance-monotonic colormaps (gray, viridis, plasma, inferno, magma, and cividis) on 50 medical visual-question-answering items from 16 SLAKE images, 64 ChestX-ray14 chest radiographs, and 200 BBBC039 fluorescence-microscopy images for exact nucleus counting. Every prompt tells the model to ignore the colormap. Even so, with three answers per colormap on the chest radiographs, the answers of all four models depend on the colormap (all Holm-adjusted p leq 0.002). For Claude, some colored map overturns the majority answer on 29 of the 64 radiographs, where resampling gray alone overturns about 4, and Qwen's accuracy falls from 0.54 under gray to between 0.32 and 0.41 under the colored maps, mostly because it abstains. With one answer per colormap, recoloring adds disagreement beyond repeated sampling in 5 of 12 model-panel cells under per-cell 95% intervals, and repeating the instruction to ignore color does not reliably reduce it. The colormap is therefore part of what a VLM sees, and it can change the answer.

  • 3 authors
·
Nov 10

MicroDetect-Net (MDN): Leveraging Deep Learning to Detect Microplastics in Clam Blood, a Step Towards Human Blood Analysis

With the prevalence of plastics exceeding 368 million tons yearly, microplastic pollution has grown to an extent where air, water, soil, and living organisms have all tested positive for microplastic presence. These particles, which are smaller than 5 millimeters in size, are no less harmful to humans than to the environment. Toxicity research on microplastics has shown that exposure may cause liver infection, intestinal injuries, and gut flora imbalance, leading to numerous potential health hazards. This paper presents a new model, MicroDetect-Net (MDN), which applies fluorescence microscopy with Nile Red dye staining and deep learning to scan blood samples for microplastics. Although clam blood has certain limitations in replicating real human blood, this study opens avenues for applying the approach to human samples, which are more consistent for preliminary data collection. The MDN model integrates dataset preparation, fluorescence imaging, and segmentation using a convolutional neural network to localize and count microplastic fragments. The combination of convolutional networks and Nile Red dye for segmentation produced strong image detection and accuracy. MDN was evaluated on a dataset of 276 Nile Red-stained fluorescent blood images and achieved an accuracy of ninety two percent. Robust performance was observed with an Intersection over Union of 87.4 percent, F1 score of 92.1 percent, Precision of 90.6 percent, and Recall of 93.7 percent. These metrics demonstrate the effectiveness of MDN in the detection of microplastics.

  • 4 authors
·
Aug 25, 2025

Reducing Domain Gap with Diffusion-Based Domain Adaptation for Cell Counting

Generating realistic synthetic microscopy images is critical for training deep learning models in label-scarce environments, such as cell counting with many cells per image. However, traditional domain adaptation methods often struggle to bridge the domain gap when synthetic images lack the complex textures and visual patterns of real samples. In this work, we adapt the Inversion-Based Style Transfer (InST) framework originally designed for artistic style transfer to biomedical microscopy images. Our method combines latent-space Adaptive Instance Normalization with stochastic inversion in a diffusion model to transfer the style from real fluorescence microscopy images to synthetic ones, while weakly preserving content structure. We evaluate the effectiveness of our InST-based synthetic dataset for downstream cell counting by pre-training and fine-tuning EfficientNet-B0 models on various data sources, including real data, hard-coded synthetic data, and the public Cell200-s dataset. Models trained with our InST-synthesized images achieve up to 37\% lower Mean Absolute Error (MAE) compared to models trained on hard-coded synthetic data, and a 52\% reduction in MAE compared to models trained on Cell200-s (from 53.70 to 25.95 MAE). Notably, our approach also outperforms models trained on real data alone (25.95 vs. 27.74 MAE). Further improvements are achieved when combining InST-synthesized data with lightweight domain adaptation techniques such as DACS with CutMix. These findings demonstrate that InST-based style transfer most effectively reduces the domain gap between synthetic and real microscopy data. Our approach offers a scalable path for enhancing cell counting performance while minimizing manual labeling effort. The source code and resources are publicly available at: https://github.com/MohammadDehghan/InST-Microscopy.

  • 2 authors
·
Dec 12, 2025

Cross-modal learning for plankton recognition

This paper considers self-supervised cross-modal coordination as a strategy enabling utilization of multiple modalities and large volumes of unlabeled plankton data to build models for plankton recognition. Automated imaging instruments facilitate the continuous collection of plankton image data on a large scale. Current methods for automatic plankton image recognition rely primarily on supervised approaches, which require labeled training sets that are labor-intensive to collect. On the other hand, some modern plankton imaging instruments complement image information with optical measurement data, such as scatter and fluorescence profiles, which currently are not widely utilized in plankton recognition. In this work, we explore the possibility of using such measurement data to guide the learning process without requiring manual labeling. Inspired by the concepts behind Contrastive Language-Image Pre-training, we train encoders for both modalities using only binary supervisory information indicating whether a given image and profile originate from the same particle or from different particles. For plankton recognition, we employ a small labeled gallery of known plankton species combined with a k-NN classifier. This approach yields a recognition model that is inherently multimodal, i.e., capable of utilizing information extracted from both image and profile data. We demonstrate that the proposed method achieves high recognition accuracy while requiring only a minimal number of labeled images. Furthermore, we show that the approach outperforms an image-only self-supervised baseline. Code available at https://github.com/Jookare/cross-modal-plankton.

  • 8 authors
·
Mar 17

Impact of Static Disorder and Dephasing on Quantum Transport in LH1-RC Models

We numerically study excitation transfer in an artificial LH1-RC complex -- an N-site donor ring coupled to a central acceptor -- driven by a narrowband optical mode and evolved under a Lindblad master equation with loss and dephasing. In the absence of disorder, the light-driven system exhibits a tall, narrow on-resonance efficiency peak (near unity for our parameters); dephasing lowers and narrows this peak without shifting its position. Off resonance, the efficiency shows environmentally assisted transport with a clear non-monotonic dependence on dephasing and a finite optimum. Under static disorder, two regimes emerge: photon-ring coupling and diagonal energetic disorder mix the drive into dark ring modes, activate dissipative channels, and depress efficiency over a detuning window, whereas intra-ring coupling disorder has a much smaller impact in the tested range; increasing the intra-ring coupling g moves dark-mode crossings away from the operating detuning and restores near-peak performance. In the ordered, symmetric, single-excitation, narrowband limit we analytically derive closed-form transfer efficiencies by projecting onto the k{=}0 bright mode and solving the photon--bright mode--acceptor trimer via a Laplace/linear-algebra (determinant) formula; these expressions include a probability-conservation identity eta + sum_k L_k = 1 that benchmarks the simulations and quantitatively predicts the resonant line shape and its dephasing-induced narrowing. A minimal ring toy model further reproduces coherent trapping and its relief by moderate dephasing (ENAQT). These analytics are exact in the ordered limit and serve as mechanistic guides outside this limit, yielding practical design rules for robust, bio-inspired light-harvesting devices.

  • 4 authors
·
Sep 23, 2025

waveOrder: generalist framework for label-agnostic computational microscopy

Correlative computational microscopy is accelerating the mapping of dynamic biological systems by integrating morphological and molecular measurements across spatial scales, from organelles to entire organisms. Visualization, measurement, and prediction of interactions among the components of biological systems can be accelerated by generalist computational imaging frameworks that relax the trade-offs imposed by multiplex dynamic imaging. This work reports a generalist framework for wave optical imaging of the architectural order (waveOrder) among biomolecules for encoding and decoding multiple specimen properties from a minimal set of acquired channels, with or without fluorescent labels. waveOrder expresses material properties in terms of elegant physically motivated basis vectors directly interpretable as phase, absorption, birefringence, diattenuation, and fluorophore density; and it expresses image data in terms of directly measurable Stokes parameters. We report a corresponding multi-channel reconstruction algorithm to recover specimen properties in multiple contrast modes. With this framework, we implement multiple 3D computational microscopy methods, including quantitative phase imaging, quantitative label-free imaging with phase and polarization, and fluorescence deconvolution imaging, across scales ranging from organelles to whole zebrafish. These advances are available via an extensible open-source computational imaging library, waveOrder, and a napari plugin, recOrder.

  • 9 authors
·
Dec 12, 2024

Label-free cell counting and viability prediction with brightfield imaging and deep learning

Cell viability assessment is a core requirement in cell culture systems, with critical applications in biopharmaceutical manufacturing and drug development. Conventionally, it is measured by adding membrane-impermeable dyes to a sample (a process called staining), which allows compromised cell membranes to be distinguished from intact ones. However, staining has several limitations: (a) chemical agents can perturb normal cellular processes of the cells being measured, (b) it is often ambiguous to assign viability to individual cells whose membrane integrity is only partially compromised. (c) photobleaching can undermine measurement accuracy over time when using fluorescent stains, and (d) staining cannot be performed in situ or in real time. Here, we show that (1) stained cells captured under brightfield imaging contain sufficient information to distinguish live and dead cells, and (2) cells captured under unstained brightfield imaging exhibit similar image features to their stained counterparts, enabling models trained on stained cells to generalize to unstained ones. We then report the development and validation of ViabiLens, an AI-assisted software for label-free cell viability analysis. The ViabiLens combines a cell detection model for localizing individual cells with a convolutional neural network (CNN) classifier for live/dead prediction, paired with an interactive UMAP-based viewer for visualizing and exploring individual cells across the sample. Evaluated on Chinese Hamster Ovary (CHO) cells spanning a wide range of viability conditions, ViabiLens achieves a mean absolute error of 2.68\% on unstained samples against fluorescence-based reference measurements. We also release a benchmark dataset for label-free cell viability analysis to facilitate future research, available at https://amirrezavazifeh.github.io/ViabiLens-Project-Page/.

  • 5 authors
·
Oct 6

Transition-Based Constrained DFT for the Robust and Reliable Treatment of Excitations in Supramolecular Systems

Despite the variety of available computational approaches, state-of-the-art methods for calculating excitation energies such as time-dependent density functional theory (TDDFT), are computationally demanding and thus limited to moderate system sizes. Here, we introduce a new variation of constrained DFT (CDFT), wherein the constraint corresponds to a particular transition (T), or combination of transitions, between occupied and virtual orbitals, rather than a region of the simulation space as in traditional CDFT. We compare T-CDFT with TDDFT and DeltaSCF results for the low lying excited states (S_{1} and T_{1}) of a set of gas phase acene molecules and OLED emitters, as well as with reference results from the literature. At the PBE level of theory, T-CDFT outperforms DeltaSCF for both classes of molecules, while also proving to be more robust. For the local excitations seen in the acenes, T-CDFT and TDDFT perform equally well. For the charge-transfer (CT)-like excitations seen in the OLED molecules, T-CDFT also performs well, in contrast to the severe energy underestimation seen with TDDFT. In other words, T-CDFT is equally applicable to both local excitations and CT states, providing more reliable excitation energies at a much lower computational cost than TDDFT. T-CDFT is designed for large systems and has been implemented in the linear scaling BigDFT code. It is therefore ideally suited for exploring the effects of explicit environments on excitation energies, paving the way for future simulations of excited states in complex realistic morphologies, such as those which occur in OLED materials.

  • 4 authors
·
Jun 2, 2021

Resolving molecular biexcited states using classical leading-order triples corrections to quantum equation-of-motion UCCSD

Excited electronic states are difficult to accurately and tractably model, particularly those exhibiting multiexcitonic character. Scalable single-reference excited state methods typically fail to describe such states as they suffer from the defects of the mean-field approximation and/or neglect higher-rank excitation operators. To address this, we derive the [T] perturbative correction to the quantum self-consistent equation-of-motion unitary coupled cluster singles and doubles (q-sc-EOM-UCCSD) method. The method captures triple excitation effects through a classical step of second-order in many-body perturbation theory following a q-sc-EOM-UCCSD calculation on a quantum computer. The perturbative correction developed has a O(N^7) classical computational time scaling. We incorporate [T] into a hybrid compute strategy wherein eigenvectors of the effective Hamiltonian from the hybrid quantum-classical q-sc-EOM-UCCSD algorithm are relayed to a classical computer which performs the postprocessing required for the [T] correction. The benefits of [T] are quantified in a benchmark covering a variety of electronically excited states of the isoelectronic CH^+ and BH molecules. We find that the addition of the [T] correction to both trotterized and full operator variants of q-sc-EOM-CCSD can offer dramatic improvements over baseline q-sc-EOM-UCCSD. Our assessment clearly demonstrates the importance of considering higher-rank excitation operators in q-sc-EOM-UCCSD, quantifies the overall success of the [T] correction, and discusses some of its limitations.

  • 6 authors
·
Oct 6

Computational illumination for high-speed in vitro Fourier ptychographic microscopy

We demonstrate a new computational illumination technique that achieves large space-bandwidth-time product, for quantitative phase imaging of unstained live samples in vitro. Microscope lenses can have either large field of view (FOV) or high resolution, not both. Fourier ptychographic microscopy (FPM) is a new computational imaging technique that circumvents this limit by fusing information from multiple images taken with different illumination angles. The result is a gigapixel-scale image having both wide FOV and high resolution, i.e. large space-bandwidth product (SBP). FPM has enormous potential for revolutionizing microscopy and has already found application in digital pathology. However, it suffers from long acquisition times (on the order of minutes), limiting throughput. Faster capture times would not only improve imaging speed, but also allow studies of live samples, where motion artifacts degrade results. In contrast to fixed (e.g. pathology) slides, live samples are continuously evolving at various spatial and temporal scales. Here, we present a new source coding scheme, along with real-time hardware control, to achieve 0.8 NA resolution across a 4x FOV with sub-second capture times. We propose an improved algorithm and new initialization scheme, which allow robust phase reconstruction over long time-lapse experiments. We present the first FPM results for both growing and confluent in vitro cell cultures, capturing videos of subcellular dynamical phenomena in popular cell lines undergoing division and migration. Our method opens up FPM to applications with live samples, for observing rare events in both space and time.

  • 6 authors
·
Sep 19, 2015

GAMMA Challenge:Glaucoma grAding from Multi-Modality imAges

Color fundus photography and Optical Coherence Tomography (OCT) are the two most cost-effective tools for glaucoma screening. Both two modalities of images have prominent biomarkers to indicate glaucoma suspected. Clinically, it is often recommended to take both of the screenings for a more accurate and reliable diagnosis. However, although numerous algorithms are proposed based on fundus images or OCT volumes in computer-aided diagnosis, there are still few methods leveraging both of the modalities for the glaucoma assessment. Inspired by the success of Retinal Fundus Glaucoma Challenge (REFUGE) we held previously, we set up the Glaucoma grAding from Multi-Modality imAges (GAMMA) Challenge to encourage the development of fundus \& OCT-based glaucoma grading. The primary task of the challenge is to grade glaucoma from both the 2D fundus images and 3D OCT scanning volumes. As part of GAMMA, we have publicly released a glaucoma annotated dataset with both 2D fundus color photography and 3D OCT volumes, which is the first multi-modality dataset for glaucoma grading. In addition, an evaluation framework is also established to evaluate the performance of the submitted methods. During the challenge, 1272 results were submitted, and finally, top-10 teams were selected to the final stage. We analysis their results and summarize their methods in the paper. Since all these teams submitted their source code in the challenge, a detailed ablation study is also conducted to verify the effectiveness of the particular modules proposed. We find many of the proposed techniques are practical for the clinical diagnosis of glaucoma. As the first in-depth study of fundus \& OCT multi-modality glaucoma grading, we believe the GAMMA Challenge will be an essential starting point for future research.

  • 29 authors
·
Feb 14, 2022

SparseSSP: 3D Subcellular Structure Prediction from Sparse-View Transmitted Light Images

Traditional fluorescence staining is phototoxic to live cells, slow, and expensive; thus, the subcellular structure prediction (SSP) from transmitted light (TL) images is emerging as a label-free, faster, low-cost alternative. However, existing approaches utilize 3D networks for one-to-one voxel level dense prediction, which necessitates a frequent and time-consuming Z-axis imaging process. Moreover, 3D convolutions inevitably lead to significant computation and GPU memory overhead. Therefore, we propose an efficient framework, SparseSSP, predicting fluorescent intensities within the target voxel grid in an efficient paradigm instead of relying entirely on 3D topologies. In particular, SparseSSP makes two pivotal improvements to prior works. First, SparseSSP introduces a one-to-many voxel mapping paradigm, which permits the sparse TL slices to reconstruct the subcellular structure. Secondly, we propose a hybrid dimensions topology, which folds the Z-axis information into channel features, enabling the 2D network layers to tackle SSP under low computational cost. We conduct extensive experiments to validate the effectiveness and advantages of SparseSSP on diverse sparse imaging ratios, and our approach achieves a leading performance compared to pure 3D topologies. SparseSSP reduces imaging frequencies compared to previous dense-view SSP (i.e., the number of imaging is reduced up to 87.5% at most), which is significant in visualizing rapid biological dynamics on low-cost devices and samples.

  • 6 authors
·
Jul 2, 2024

Quasi-periodic pulsations in extreme-ultraviolet brightenings

Context. Extreme-ultraviolet (EUV) observations have revealed small-scale transient brightenings that may share common physical mechanisms with larger-scale solar flares. A notable feature of solar and stellar flares is the presence of quasi-periodic pulsations (QPPs), which are considered a common and potentially intrinsic characteristic. Aims. We investigate the properties of QPPs detected in EUV brightenings, which are considered small-scale flares, and compare their statistical properties with those observed in solar and stellar flares. Methods. We extracted integrated light curves of 22,623 EUV brightenings in two quiet Sun regions observed by the Solar Orbiter/Extreme Ultraviolet Imager and identified QPPs in their light curves using Fourier analysis. Results. Approximately 2.7 % of the EUV brightenings exhibited stationary QPPs. The QPP occurrence rate increased with the surface area, lifetime, and peak brightness of the EUV brightenings. The detected QPP periods ranged from approximately 15 to 260 seconds, which is comparable to the periods observed in solar and stellar flares. Consistent with observations of QPPs in solar and stellar flares, no correlation was found between the QPP period and peak brightness. However, unlike the trend observed in solar flares, no correlation was found between the QPP period and lifetime/length scale. Conclusions. The presence of QPPs in EUV brightenings supports the interpretation that these events may be small-scale manifestations of flares, and the absence of period scaling with loop length further suggests that standing waves may not be the primary driver of QPPs in these events.

  • 8 authors
·
Apr 21, 2025